| General Information |
| Part Number | FO112S-3T-LSZH |
| Description | 12 Core 9/125 SM Armored 3 Tube Fiber Optical Cable with LSZH Jacket |
| Cable Type | Indoor/Outdoor Type Fiber Optical Cable |
| Fiber Type | Single Mode, ITU-T G652D |
| Standards Conformance | ANSI/TIA/EIA-569B.3, ISO/IEC 11801, CENELEC EN 50173 |
| Cable Construction |
| Number of Fibers | 12 |
| Number of Loose Tubes × Number of Fibers per Tube | 3 × 4 |
| Central Strength Member – Diameter | 2,2 ± 0,05 mm |
| Central Strength Member – Material | FRP |
| Central Strength Member – CSM Oversheathing Diameter | --- |
| Loose Tube – Material | PC+PBT |
| Loose Tube – Diameter | 2,15 ± 3% mm |
| Loose Tube – Type of Filling Compound | Thixotropic jelly |
| Filler (if required) – Material | PE |
| Core Filling Compound – Material | Petroleum gel for water blocking |
| Core Wrapping – Material | Polyester tape |
| Periphery Strength Members – Material | Glass yarn |
| Inner Sheath – Material | LDPE |
| Inner Sheath – Thickness | 1,0 mm (nominal) |
| Armor & Rodent Protection – Material | Two sides plastic clad and corrugated steel tape |
| Armor & Rodent Protection – Thickness | 0,15 mm |
| Outer Sheath – Material | UV stabilized LSZH thermoplastic material |
| Outer Sheath – Thickness | 1,3 mm (nominal) |
| Cable Diameter | 13,2 mm ± 0,2 |
| Cable Weight (approx.) | 200 kg/km |
| Mechanical Characteristics |
| Mechanical Tests |
| Test | Test Standard | Specified Value | Acceptance Criteria |
| Tensile Force – Installation | IEC 60794-1-2-E1 | Max. 2700 N | Δα ≤ 0,05 dB, fiber strain ≤ 0,33 % |
| Tensile Force – Operation | IEC 60794-1-2-E1 | Max. 1700 N | Δα ≤ 0,05 dB, no fiber strain; Δα reversible |
| Crush Resistance | IEC 60794-1-2-E3 | Max. 5000 N | No fibers break; Δα ≤ 0,05 dB, no damage |
| Impact | IEC 60794-1-2-E4 | 10 Nm, 3 impacts at different points, R = 300 mm | No damage |
| Torsion | IEC 60794-1-2-E7 | 100 N, ± 180°, 5 cycles | Δα ≤ 0,05 dB, no damage |
| Repeated Bending | IEC 60794-1-2-E6 | R = 20 × D, 100 N load, 30 cycles | — |
| Cable Bend | IEC 60794-1-2-E11 | R = 20 × D (D: cable diameter), 4 turns, 3 cycles | — |
|
| Note | All optical measurements are at 1550 nm. |
| Environmental Characteristics |
| Environmental Tests |
| Test | Test Standard | Specified Value | Acceptance Criteria |
| Water Penetration | IEC 60794-1-2-F5B | 1 meter specimen, 1 m water altitude | No leakage from the opposite end of the cable within 24 hours |
| Temperature Cycling | IEC 60794-1-2-F1 | Storage -40 ~ +80 ºC; Installation -5 ~ +50 ºC; Operation -30 ~ +70 ºC | Δα < 0,05 dB/km at 1550 nm |
|
| Identification |
| Cable Marking | 1 m ±1% intervals in white color with hot print |
| Identification of Cable | ORingNetworking <year of manufacture> <number of fibers> F <fiber type> <length marking in meter> |
| Color of Filler (if required) | Black |
| Color of Loose Tubes | 1. Blue, 2. Orange, 3. Green, 4. Brown, 5. Grey, 6. White |
| Color of Fibers | 1. Blue, 2. Orange, 3. Green, 4. Brown |
| Color of Outer Sheath | Black |
| Note | The inscription given above is the standard imprint; it can be changed on request. Other tube and fiber colors are optional. |
| Delivery Information |
| Drum Length / Tolerance | 2000 m ± 5% |
| Drum Flange Diameter | 1250 mm |
| Drum Core Diameter | 580 mm |
| Outside Width | 780 mm |
| Central Hole Diameter | 85 mm |
| Note | Drum dimensions can change depending on the cable length on the drum. Standard delivery length is 2 km; other lengths are optional. |
| Fiber Specifications (Standard SM Fiber, ITU-T G652D) |
| Attenuation (max.) | 0.36 dB/km (1310 nm); 0.22 dB/km (1550 nm) |
| Mode Field Diameter (MFD) | 9.2±0.5 µm |
| Chromatic Dispersion (max.) | 3.5 ps/(nm×km) (1310 nm); 18 ps/(nm×km) (1550 nm) |
| Cladding Diameter | 125±1 µm |
| Core-Clad Concentricity Error (max.) | 1 µm |
| Zero Dispersion Wavelength | 1300 nm ≤ λ ≤ 1324 nm |
| Cladding Non-Circularity (max.) | %2 |
| Coating Diameter | 250±15 µm |
| Cut-off Wavelength | 1150 nm ≤ λ ≤ 1330 nm |
| Proof Test | 8.4 N |
| Proof Test Strain | %1.00 |
| Standard Approval | IEC 793-1 |
| Ordering Information |
| FO104S-1T-LSZH | 4 Core 9/125 SM Armored 1 Tube Fiber Optical Cable with LSZH Jacket |
| FO108S-2T-LSZH | 8 Core 9/125 SM Armored 2 Tube Fiber Optical Cable with LSZH Jacket |
| FO112S-3T-LSZH | 12 Core 9/125 SM Armored 3 Tube Fiber Optical Cable with LSZH Jacket |
| FO116S-4T-LSZH | 16 Core 9/125 SM Armored 4 Tube Fiber Optical Cable with LSZH Jacket |
| FO120S-5T-LSZH | 20 Core 9/125 SM Armored 5 Tube Fiber Optical Cable with LSZH Jacket |
| FO124S-6T-LSZH | 24 Core 9/125 SM Armored 6 Tube Fiber Optical Cable with LSZH Jacket |
| Note | All of the above models are available under the ORingNetworking brand name. |