| Conductor |
| Material | Oxygen free copper (99.97% purity) |
| Conductor Structure | 0.5 mm ± 0.01 mm (0.02" ± 0.0004") |
| American Wire Gauge | 24AWG |
| Insulation |
| Insulating Material | HDPE |
| Min. Average Thickness | 0.18 mm (0.01") |
| Insulation Diameter | 0.90 mm ± 0.10 mm (0.04" ± 0.0004") |
| Insulation Color | 8 cores: blue, white/blue; orange, white/orange; green, white/green; brown, white/brown |
| Rip Cord |
| Material | Polyester |
| Specification | 500D |
| Sheath |
| Min. Average Thickness | 0.5 mm (0.02") |
| Sheath Material | PVC |
| Sheath Diameter | 5.1 mm ± 0.30 mm (0.20" ± 0.01") |
| Sheath Color | White |
| Electrical |
| Max. DC Resistance of a Single Conductor | 9.5 Ω@100 m (328.08 ft) |
| Min. Insulation Resistance | 5000 MΩ·km |
| Max. DC Resistance Unbalance | 2% (pair intra), 4% (pairs inter) |
| Dielectric Strength | No breakdown with 1 kV DC for 1 min |
| Transmission |
| Characteristic Impedance | 100 Ω ± 15 Ω |
| Near-end Crosstalk | ≥35.3 dB/100 m@100 MHz |
| Max. Attenuation | 22 dB/100 m@100 MHz |
| Return Loss | ≥20.1 dB/100 m@100 MHz |
| Mechanical |
| Tensile Strength | Sheath ≥13.5 MPa, insulation ≥16 MPa |
| Elongation at Break | Sheath ≥150%, insulation ≥300% |
| Installation Bending Radius | >8 times of outer cable diameter |
| Conductor Elongation at Break | ≥10% |
| Environmental |
| Shrinkage of Insulation | ≤5% |
| Color Migration Resistance of Insulation | No migration |
| Sheath Tensile Strength and Elongation at Break after Aging | ≥12.5 MPa, ≥125% |
| Low Temperature Bending Test | No cracking after the test |
| Heat Shock Test | No cracking after the test |
| Operating Temperature | –20 °C to +60 °C (–4 °F to +140 °F) |
| Installation Temperature | 0 °C to +50 °C (+32 °F to +122 °F) |
| Storage Temperature | –10 °C to +40 °C (+14 °F to +104 °F) |
| Storage Humidity | <60% (RH) |
| Security |
| Vertical Flame Test | Comply with IEC 60332-1-2 |
| Packaging |
| Cable Length | 305.0 m ± 2 m (1,000.66 ft ± 6.56 ft) |
| Packaging Method | 305 m (1,000 ft) a carton, one carton with 2 inner cartons |
| Packaging Dimensions | 364 mm × 364 mm × 216 mm (14.33" × 14.33" × 8.50") (L × W × H) |
| Transport Package Dimensions | 447 mm × 382 mm × 386 mm (17.60" × 15.04" × 15.20") (L × W × H) |
| Net Weight | 8.9 kg ± 0.4 kg (19.62 lb ± 0.88 lb) |
| Gross Weight | 9.5 kg ± 0.4 kg (20.94 lb ± 0.88 lb) |
| Compliance Standard |
| Compliance Standard | ISO/IEC 11801, IEC 61156-5 |
| Certifications |
| Certifications | CPR Eca |
| Flame-retardant Standard |
| Compliance Standard | EN 50575 |
| Transmission Characteristics (100 m at 20 °C) (328.08 ft at 68 °F) |
| Frequency (MHz) | Phase delay ≤ ns | IL ≤ dB | NEXT ≥ dB | PS NEXT ≥ dB | ACRF ≥ dB |
| 1 | 570 | 2.0 | 65.3 | 62.3 | 63.8 |
| 4 | 552 | 4.1 | 56.3 | 53.3 | 51.8 |
| 8 | 547 | 5.8 | 51.8 | 48.8 | 45.7 |
| 10 | 545 | 6.5 | 50.3 | 47.3 | 43.8 |
| 16 | 543 | 8.2 | 47.2 | 44.2 | 39.7 |
| 20 | 542 | 9.3 | 45.8 | 42.8 | 37.8 |
| 25 | 541 | 10.4 | 44.3 | 41.3 | 35.8 |
| 31.25 | 540 | 11.7 | 42.9 | 39.9 | 33.9 |
| 62.5 | 539 | 17.0 | 38.4 | 35.4 | 27.9 |
| 100 | 538 | 22.0 | 35.3 | 32.3 | 23.8 |
| Frequency (MHz) | PS ACRF ≥ dB | RL ≥ dB | Delay skew ≤ ns | Zc (Ω) |
| 1 | n/s | n/s | n/s | n/s |
| 4 | 60.8 | 23.0 | 45.0 | 100±15 |
| 8 | 42.7 | 24.5 | 45.0 | 100±15 |
| 10 | 40.8 | 25.0 | 45.0 | 100±15 |
| 16 | 36.7 | 25.0 | 45.0 | 100±15 |
| 20 | 34.8 | 25.0 | 45.0 | 100±15 |
| 25 | 32.8 | 24.3 | 45.0 | 100±15 |
| 31.25 | 30.9 | 23.6 | 45.0 | 100±15 |
| 62.5 | 24.9 | 21.5 | 45.0 | 100±15 |
| 100 | 20.8 | 20.1 | 45.0 | 100±15 |
Note: Executive standard for the above parameters: ANSI/TIA-568-C.2-2009 |