Stock Code: RF5078
| Physical Properties | |
|---|---|
| Inner Conductor | Smooth Copper Tube — 0.352 in (8.95±0.05 mm) |
| Insulation | Physically Foamed PE — 0.885 in (22.50±0.40 mm) |
| Outer Conductor | Ring Corrugated Copper — 0.980 in (24.90±0.30 mm) |
| Jacket | PE or Fire Retardant PE — 1.074 in (27.30±0.20 mm) |
| Electrical Properties | |
| Cut-off Frequency | 5.0 GHz |
| Characteristic Impedance | 50 Ω |
| Propagation Velocity (Nom.) | 88 % |
| Capacitance (Nom.) | 75 pF/m |
| Screening Attenuation | >>120 dB |
| Peak Power | 91 kW |
| DC Breakdown Voltage | 6.0 kV |
| Insulation Resistance | >5×103 MΩ·km |
| Mechanical Properties | |
| Bending Radius — Single (mm) | 120 |
| Bending Radius — Repeated (mm) | 250 |
| Bending Radius — Moving (mm) | 500 |
| Pulling Strength | 1470 N |
| Crush Resistance | 1.4 kg/mm |
| Recommended Temperature — Storage | -70 ~ +85°C |
| Recommended Temperature — Installation | -40 ~ +60°C |
| Recommended Temperature — Operation | -55 ~ +85°C |
| Attenuation and Average Power | |
| Frequency (MHz) | 10 / 100 / 200 / 450 / 800 / 900 / 1000 / 1500 / 1800 / 2000 / 2500 / 3000 |
| Attenuation (dB/100 m) | 0.366 / 1.19 / 1.72 / 2.65 / 3.63 / 3.88 / 4.12 / 5.18 / 5.75 / 6.11 / 6.95 / 7.76 |