Stock Code: IGPS-1080-24V









| ORing Switch Model | IGPS-1080-24V |
| Physical Ports | |
|---|---|
| 10/100/1000Base-T(X) Ports in RJ45, Auto MDI/MDIX, with P.S.E | 8 |
| Technology | |
| Ethernet Standards | IEEE 802.3 for 10Base-T IEEE 802.3u for 100Base-TX IEEE 802.3ab for 1000Base-T IEEE 802.3x for Flow control IEEE 802.3at PoE specification |
| MAC Table | 4K |
| Packet Buffer | 1.5 Mbits |
| Processing | Store-and-Forward |
| Jumbo Frame | 9720 Bytes |
| Switch Properties | Switching latency: 7 µs Switching bandwidth: 16 Gbps Throughput (packet per second): 11.58 Mpps @ 64-Byte packet |
| LED Indicators | |
| Power Indicator (PWR) | Green: Power LED × 2 |
| Fault Indicator | Amber: indicates PWR1 or PWR2 failure |
| RJ45 Port Indicator | Upper LED — Link/Act indicator: green for port Link/Act Lower LED — PoE indicator: green when PoE power is enabled |
| DIP Switch | |
| DIP Switch 1 | Power 1 fail warning: ON for enable, OFF for disable |
| DIP Switch 2 | Power 2 fail warning: ON for enable, OFF for disable |
| Fault Contact | |
| Relay | Relay output with carry capacity of 1 A at 24 VDC |
| Power | |
| Redundant Input Power | Dual 12~57 VDC (24 VDC for vehicle use) |
| Power Consumption (Typ.) | 5.4 Watts |
| PoE Power Budget | 60 Watts (12~24 VDC) / 120 Watts (24.1~57 VDC) |
| Overload Current Protection | Present |
| Reverse Polarity Protection | Present |
| Physical Characteristics | |
| Enclosure | IP-30 metal |
| Dimensions (W × D × H) | 41 (W) × 114.9 (D) × 144.3 (H) mm |
| Weight | 676 g |
| Environmental | |
| Storage Temperature | -40 °C ~ 85 °C (-40 °F ~ 185 °F) |
| Operating Temperature | -40 °C ~ 75 °C (-40 °F ~ 167 °F) |
| Operating Humidity | 5% ~ 95% non-condensing |
| Regulatory Approvals | |
| EMC | CE EMC (EN 55035, EN 55032), EN 50121-4 (compliant), FCC Part 15 B |
| EMI | EN 55032, CISPR 32, EN 61000-3-2, EN 61000-3-3, FCC Part 15 B Class A |
| EMS | EN 55035 (IEC/EN 61000-4-2 (ESD), IEC/EN 61000-4-3 (RS), IEC/EN 61000-4-4 (EFT), IEC/EN 61000-4-5 (Surge), IEC/EN 61000-4-6 (CS), IEC/EN 61000-4-8 (PFMF), IEC/EN 61000-4-11 (DIP)) |
| Other | E-MARK |
| Shock | IEC 60068-2-27 |
| Free Fall | IEC 60068-2-31 |
| Vibration | IEC 60068-2-6 |
| Safety | UL 61010-1, UL 61010-2-201 |
| MTBF | 532,527 hours (Standard: Telcordia SR-332) |
| Warranty | 5 years |