| General Specifications |
|---|
| Product Type | Fiber Optic Patch Cord |
| Connector (Side A) | LC Duplex, Multimode (M/M) |
| Connector (Side B) | LC Duplex, Multimode (M/M) |
| Cable | Zipcord, Multimode (M/M), 62.5/125, 2.0 mm, PVC, Orange |
| Insertion Loss | ≤ 0.3 dB |
| Fan-out Leg Length | 2 × 150 ±10 mm |
| Wiring Table |
|---|
| Fiber Assignment | | Fiber # | Side A | Side B |
|---|
| 1 | A | B | | 2 | B | A |
|
| Cable Specifications |
|---|
| Number of Fibers | 2 |
| Fiber Type | Corning 62.5/125 or equivalent |
| Core Diameter | 62.5 ±0.7 µm |
| Cladding Diameter | 125 ±1 µm |
| Primary Coating Diameter | 245 ±10 µm |
| Primary Coating Material | Acrylate |
| Buffer Diameter | 900 µm ±50 µm |
| Buffer Material | Riser rated material or better |
| Buffer Color | White & Yellow, per EIA/TIA 598 |
| Number of Fibers per Sub-Unit | 1 |
| Outer Jacket Dimension | (2.0 mm +0/-0.2 mm) × (3.7 mm to 4.1 mm) |
| Outer Jacket Material | PVC |
| Outer Jacket Color | Orange, per EIA/TIA 598 |
| Flammability Rating | Riser (OFNR) per UL-1666 |
| Cable Construction | Tight Buffered |
| Strength Member Material | Aramid Yarn |
| Fiber Proof Strength | ≥ 100 kpsi |
| Tensile Load | 100 N operating / 200 N installation |
| Buffer Stripability | Per GR-409 |
| Jacket Shrinkage | Per GR-20 |
| Attenuation | ≤ 3.5 dB/km @850 nm; ≤ 1.5 dB/km @1300 nm |
| OFL Bandwidth | 200 MHz·km @850 nm; 500 MHz·km @1300 nm |
| Numerical Aperture (NA) | 0.275 ±0.015 |
| Core to Cladding Concentricity | ≤ 3.0 µm |
| Cutoff Wavelength | N/A |
| Operating Temperature | -40°C ~ +85°C |
| Installation Temperature | -40°C ~ +85°C |
| Storage Temperature | -40°C ~ +85°C |
| Impact Resistance | ≤ 0.74 N.m |
| Crush Resistance | ≤ 3.5 N/mm |
| Minimum Bend Radius | Installation: 20 × O.D.; Long term: 10 × O.D. |
| RoHS Compliance | Yes |