| Ethernet Interface | |
|---|---|
| Number of ports | 8x 10/100Base-T(X) |
| Cable types according to IEEE 802 | Shielded Twisted Pair (STP) or Unshielded Twisted Pair (UTP), Category 5 |
| Data Rate | 10 Mbit/s or 100 Mbit/s |
| Maximum Cable Length | 100 m (Twisted Pair; with Category 5 cable according to DIN EN 50 173-1) |
| Termination | M12 D-coding |
| Contact Assignment M12 D-Coding | Pin 1: TD+ Pin 3: TD- Pin 2: RD+ Pin 4: RD- PoE voltage is supplied over the data signal pairs; phantom power. |
| Diagnostics (per port) LED Link |
Status / Data Transfer Rate: On – Link – Green – 10 Mbit/s Blinking – Activity – Yellow – 100 Mbit/s |
| LED PoE | Off: PoE device not connected. Green: PoE device connected. Red: PoE device connected with error. |
| Topology | Line, Ring, Star or mixed |
| Power Supply | |
| Non-PoE Mode • Input voltage • Permitted range (min/max) • Input current |
• 24 / 48 V DC • 12 ... 55 V DC • Approx. 350 mA (at 24 V DC) |
| PoE Mode • Input voltage • Max. input current • Output voltage • Output power • Output current • Type |
• 48 V DC (46 ... 55 V DC) • Max. 3.0 A (at 48 V DC / 350 mA load per port) • 48 V DC (46 ... 57 V DC) • 15.4 W per port • 0.35 A • Mode A |
| Termination | M12 A-coding, male, only for Non-PoE mode as redundant power supply |
| Contact Assignment M12 A-coding | Contact No. – Power Supply – Potential – Mode 1 – US1 – 48 V DC / 24 V DC – PoE / Non-PoE 2 – US1 – 0 V – PoE / Non-PoE 3 – US2 – 0 V – Non-PoE 4 – US2 – 24 V DC – Non-PoE US 1 ... first operating power supply US 2 ... second operating power supply |
| Diagnostics LED Pwr x9 | Pwr PoE • Green • Off LED Fault • Red* LED Status • Green • Red |
Pwr x9 (Switch) / Pwr PoE (Mode PoE) Power Supply connected: >46 V DC Power Supply not connected: <46 V DC Fault detected (configurable via web interface or SNMP on event) * ... also briefly ON during startup PoE ok <46 V DC |
| Design Features | |
| Body material | Metal (powder coated) |
| Dimensions (W x H x D) | 130 x 166 x 50 mm |
| Degree of protection according to DIN 60 529 | IP30 |
| Mounting | Wall mounting, flat (4x M6 screws) |
| Weight | Approx. 0.85 kg |
| Environmental Conditions | |
| Operating Temperature | –40 °C ... +70 °C |
| Storage Temperature | –40 °C ... +85 °C |
| Relative Humidity | 10 % ... 95 % (non-condensing) |
| Mechanical Robustness | |
| Shock | IEC 60 068-2-27, IEC 61 373 |
| Vibration | IEC 60 068-2-6 |
| Rail standard | EN 50 155 |
| Standards | |
| EMC Standards | IEC 61 000-4-2 IEC 61 000-4-3 IEC 61 000-4-4 IEC 61 000-4-5 IEC 61 000-4-6 IEC 61 000-4-8 EN 55 022 EN 55 011 Class A EN 55 022 Class A EN 50 081 EN 50 155 EN 50 121-3-2 |