Stock Code: RG-S5750-48GT/4SFP-P








| Hardware Specifications | RG-S5750-24GT/8SFP-E | RG-S5750-48GT/4SFP-E | RG-S5750-24SFP/8GT-E | RG-S5750-24GT/8SFP-P | RG-S5750-48GT/4SFP-P | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Ports | 24 10/100/1000BASE-T ports 8 100/1000BASE-X SFP ports (combo) | 48 10/100/1000BASE-T ports 4 100/1000BASE-X SFP ports (combo) | 24 100/1000BASE-X SFP ports 8 10/100/1000BASE-T ports (combo) | 24 10/100/1000BASE-T ports (PoE+) 8 100/1000BASE-X SFP ports (combo) | 48 10/100/1000BASE-T ports (PoE+) 4 100/1000BASE-X SFP ports (combo) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Expansion Slots | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Modular Power Slots |
None | None | 2 | 2 | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Expansion Modules |
1-port 10G SFP+ module 2-port 10G SFP+ module 4-port 10G SFP+ module 2-port 10/100/1000BASE-T/100/1000BASE-X SFP (combo) module |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Management Interfaces |
1 console port 1 USB 2.0 port |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Switching Capacity |
256Gbps | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Packet Forwarding Rate |
96Mpps | 132Mpps | 96Mpps | 96Mpps | 132Mpps | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| PoE | None | None | None | Supported | Supported | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ARP Table | Up to 4,000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MAC Address | Up to 16k | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Routing Table Size |
Up to 13K | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| IP Host Entries (IPv4/IPv6) |
Up to 13K | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ACL Entries | Up to 3K | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| VLAN | 4K 802.1q VLANs, Port-based VLAN, MAC-based VLAN, Protocol-based VLAN, Private VLAN, Voice VLAN, QinQ, IP subnet-based VLAN, GVRP | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| QinQ | Basic QinQ, Flexible QinQ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Link Aggregation | Support LACP | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Port Mirroring | One-to-one mirroring, Flow-based mirroring, Mirroring across devices, AP port mirroring, RSPAN | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Spanning Tree Protocols | IEEE802.1d STP, IEEE802.1w RSTP, Standard 802.1s MSTP, Port fast, BPDU filter, BPDU guard, TC guard, TC protection, ROOT guard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| DHCP | DHCP server, DHCP client, DHCP snooping, DHCP relay, IPv6 DHCP snooping, IPv6 DHCP client, IPv6 DHCP relay | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Multiple Spanning Tree Protocol (MSTP) Instances | 64 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Maximum Aggregation Port (AP) |
Up to 120 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Virtual Routing and Forwarding (VRF) Instances |
512 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| VSU (Virtual Switch Unit) |
Supported (up to 8 stack members) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| L2 Features | MAC, ARP, VLAN, Basic QinQ, Flexible QinQ, Link aggregation, Mirroring, STP, RSTP, MSTP, Broadcast storm control, IGMP v1/v2/v3 snooping, IGMP filter, IGMP fast leave, DHCP, Jumbo frame, RLDP, LLDP, REUP, G.8032 ERPS, Layer 2 protocol tunnel | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Layer 3 Features | ARP proxy, Ping, Traceroute, Equal-Cost Multi-Path Routing (ECMP), URPF, Neighbor Discovery, ISATAP | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Layer 3 Protocols (IPv4) |
Static routing, RIP, RIPng, BGP4, BGP4+, OSPFv2/v3, IS-IS | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| IPv4 Features | Ping, Traceroute, URPF | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| IPv6 Features | ICMPv6, IPv6 Ping, IPv6 Tracert, Manually configure local address, Automatically create local address, Neighbor Discovery, 0-128 bit mask, IPv4 over IPv6 tunnel, GRE tunnel | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Basic IPv6 Protocols |
IPv6 addressing, Neighbor Discovery (ND), ICMPv6, IPv6 Ping and IPv6 Tracert | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| IPv6 Routing Protocols |
Static routing, RIP, RIPng, BGP4, BGP4+, OSPFv2/v3 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| IPv6 Tunnel Features |
IPv4 over IPv6 tunnel, GRE tunnel | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Multicast | IGMP v1/v2/v3, IGMP v1/v2/v3 snooping, IGMP proxy, IGMP filter, IGMP fast leave, Multicast routing protocols (PIM-DM, PIM-SM, PIM-SSM), MLD snooping, MLD, PIM for IPv6, MSDP, Multicast static routing | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MPLS | MPLS L3 VPN | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| G.8032 | Supported | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ACL | Standard/Extended/Expert ACL, Extended MAC ACL, IPv6 ACL, ACL logging, ACL counter, ACL remark | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| QoS | 802.1p/DSCP traffic classification; Multiple queuing mechanisms such as SP, WRR, DRR, SP+WRR, SP+DRR; Input/output port-based rate limiting; Port-based traffic identification; Each port supports 8 queue priorities | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| IPv6 ACL | Supported | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Reliability | VSU (technology for virtualization multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) |
VSU (technology for virtualization multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) |
VSU (technology for virtualization multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module |
VSU (technology for virtualization multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module |
VSU (technology for virtualization multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Security | Binding of IP address, MAC address and port address; Binding of IPv6, MAC address and port address; Filter invalid MAC addresses; Port-based and MAC-based 802.1x; MAB; Portal and Portal 2.0 authentication; ARP inspection; Rate limiting of ARP packets; Network gateway anti-ARP spoofing; Broadcast suppression; Hierarchical management administrators and password protection; RADIUS and TACACS+; AAA security authentication (IPv4/IPv6) for device login; SSH and SSH V2.0; BPDU protection; IP source protection; CPP, NFPP; Port protection | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Manageability | SNMPv1/v2c/v3, CLI (Telnet/Console), RMON (1, 2, 4, 9), SSH, Syslog/Debug, NTP, FTP, TFTP | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Other Protocols | FTP, TFTP, DNS client | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Dimensions (W x D x H) (mm) |
440×260×44 | 440×300×44 | 440×300×44 | 440×400×44 | 440×420×44 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Rack Height | 1RU | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Weight | 3.9kg | 4.4kg | 4kg | 7.3kg | 8kg | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MTBF | >200 Thousand hours | >200 Thousand hours | >346 Thousand hours | >231 Thousand hours | > 219 Thousand hours | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Lightning Protection |
6KV | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| RPS | Supported | Supported | None | None | None | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Safety Standards | IEC 60950-1, EN 60950-1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Emission Standards | EN 300 386, EN 55022/55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Power Supply | Rated voltage range: 100V to 240V Maximum voltage range: 90V to 264V Frequency: 50-60Hz Rated current: 2A |
Rated voltage range: 100V to 240V Maximum voltage range: 90V to 264V Frequency: 50-60Hz Rated current: 2A |
AC input: Rated voltage range: 100V to 240V AC, 50- 60Hz Maximum voltage range: 90V to 264V AC, 50-60Hz Overvoltage protection: 13.4V to 16V Overcurrent protection: 6A to 12A |
AC input: Rated voltage range: 100V to 240V AC Frequency: 50-60Hz Overvoltage protection: 54V: -57V to -60V 12V: 13.4V to 16V Overcurrent protection: 54V: 8A to 10A 12V: 12A to 16A |
AC input: Rated voltage range: 100V to 240V AC Frequency: 50-60Hz Overvoltage protection: 54V: -57V to -60V 12V: 13.4V to 16V Overcurrent protection: 54V: 8A to 10A 12V: 12A to 16A |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Power Consumption |
43W (w/o expansion module) 60W (w/ expansion module) |
72W (w/o expansion module) 90W (w/ expansion module) |
Dual power: 34W (w/o expansion module) 50W (w/expansion module) Single power: 33W (w/o expansion module) 48W (w/o expansion module) |
<50W (both w/o expansion modules and PD) <65W (w/expansion modules but w/o PD) <900W (w/PD but w/o expansion modules) <915W (both w/ expansion modules and PD) |
<80W (both w/o expansion modules and PD) <95W (w/expansion modules but w/o PD) <930W (w/PD but w/o expansion modules) <945W (both w/ expansion modules and PD) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| PoE Power Consumption |
- | - | - | 370W | 370W | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Temperature | Operating temperature: 0°C to 50°C Storage temperature: -40°C to 70°C |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Humidity | Operating humidity: 10% to 90% relative humidity Storage humidity: 5% to 95% relative humidity |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||