Stock Code: LinkRunner® G2
| General | |
|---|---|
| Dimensions | 3.8 in x 7.7 in x 1.6 in (9.7 cm x 19.6 cm x 4.1 cm) |
| Weight | 18 oz (0.51 kg) |
| Battery | Rechargeable lithium-ion battery pack (3.6 V, 6 Ah, 21 Wh) |
| Battery Life | Typical operating life is 4 hours. Typical charge time is 3 hours. |
| Display | 5.0 in color LCD with capacitive touch screen (480 x 800 pixels) |
| Keypad | 1-key elastometric (power only) |
| Host Interface | Micro USB On-the-Go port |
| USB Port | USB 2.0 Type A port |
| SD Card Slot | Supports Micro SD |
| Cable Test | Pair length, crossed, reversed and distance to open, short, split |
| Tone Generator | Digital tone: [455 KHz]; Analog tones: [400 Hz, 1 KHz] |
| Ports | RJ-45 copper port 10/100/1000BASE-T. 100/1000BASE-X. Fiber adapter port. Fiber port supports standard SFP |
| External AC Adapter / Charger | AC input 90-264 Vac 48-62 Hz input power DC output 15 Vdc at 2 amps or RJ-45 via PoE |
| Environmental | |
| Operating Temperature | 32°F to 113°F (0°C to +45°C) NOTE: The battery will not charge if the internal temperature of the tester is above 122°F (50°C) |
| Operating Relative Humidity (% RH without condensation) | 90% (50°F to 95°F; 10°C to 35°C); 75% (95°F to 113°F; 35°C to 45°C) |
| Shock and Vibrations | 1 m drop test, Random, 3.8 grms, 5 Hz-500 Hz (Class 2) |
| Safety | IEC 61010-1:2010: Pollution degree 2 |
| Altitude | 4,000 m; Storage: 12,000 m |
| EMC | IEC 61326-1:2013: Basic Electromagnetic Environment; CISPR 11: Group 1, Class A |