Stock Code: DRL-48V120W1EN
| OUTPUT | |
|---|---|
| Output Current | 2.5A |
| Output Voltage | 48V |
| Output Voltage Range | 43.2-52.8Vdc |
| Output Voltage Adjustment Range | 43.2-52.8Vdc |
| Output Power | 120W |
| Line Regulation | ± 0.5% @ 115Vac & 230Vac |
| Load Regulation | ± 0.5% |
| PARD (Ripple and Noise) | < 200mVpp @ 0°C to +70°C < 600mVpp @ -30°C to 0°C |
| Start-up Time | 500ms typ. @ 115Vac & 230Vac |
| Hold-up Time | 10ms typ. @ 115Vac (100% load) 16ms typ. @ 230Vac (100% load) |
| Dynamic Response (O/P Voltage Overshoot and Undershoot) | ± 10% @ 115Vac & 230Vac input, 10-100% load (Slew Rate: 2.5A/µS, 50% duty cycle @ 5Hz & 10KHz) |
| Start-up with Capacitive Load | 3,000µF Max |
| Rise Time | 30ms typ. @ 115Vac & 230Vac |
| INPUT | |
| Input Voltage (Nominal) | 100-240Vac |
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Input Current | 2.1A typ. @115Vac, 1.3A typ. @230Vac |
| Efficiency at 100% Load | 89.5% typ. @230Vac |
| Max. Inrush Current | 35A typ. @230Vac |
| Leakage Current | < 0.5mA @ 240Vac |
| Housing Chassis/Cover | Aluminium / SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Input Terminal | 3 pins (rated 300V/30A) |
| Output Terminal | 4 pins (Rated 300V/20A) |
| Noise Sound Pressure Level (SPL) | < 25dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Unit Weight | 0.45kg (0.99 lb) |
| Dimensions | 123.6 x 30 x 116.8 mm 4.87" x 1.18" x 4.60" |
| ENVIRONMENT | |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10Hz - 500Hz @ 19.6 m/s² (2G peak); 10 minutes per cycle, 60 minutes for X direction |
| Shock Test (Operating) | IEC 60068-2-27, Half-Sine Wave: 10G for 11ms duration; 1 time in X axis |
| Operating Temperature | -40°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | > 1.67% / °C Power De-rating rate with 40°C @115Vac > 2.5% / °C Power De-rating rate with 50°C @230Vac |
| Operating Humidity | 20 to 95% RH (Non-condensing) |
| Shock Test (Non-operating) | IEC 60068-2-27, Half-Sine Wave: 50G for 11ms duration; 3 times per direction, total 9 times |
| Vibration (Non-operating) | IEC 60068-2-6, Random: 5Hz - 500Hz (2.09G); 20 minutes per axis for all X, Y, Z directions |
| Operating Altitude | 0 to 5,000 Meters (16,400 feet) |
| Pollution Degree | 2 |
| Overvoltage Category | II (Compliance with EN 62477-1 OVC III with 2000 meter altitude) |
| PROTECTIONS | |
| Over Voltage | <64.8V, SELV Output, Latch Mode |
| Overload / Over Current | 105% - 150% of Nominal Load Current, Auto-recovery Continuous Current Limit Mode*5 (Vo>80%) |
| Over Temperature | Latch Mode |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery) |