Stock Code: EDR-120-48
| General | |
|---|---|
| Model | EDR-120-48 |
| Product Type | 120W Single Output Industrial DIN Rail Power Supply |
| Output | |
| DC Voltage | 48V |
| Rated Current | 2.5A |
| Current Range | 0 ~ 2.5A |
| Rated Power | 120W |
| Ripple & Noise (max.) | 150mVp-p |
| Voltage Adj. Range | 48 ~ 55V |
| Voltage Tolerance | ±1.0% |
| Line Regulation | ±0.5% |
| Load Regulation | ±1.0% |
| Setup / Rise Time | 1200ms, 60ms/230VAC; 2500ms, 60ms/115VAC at full load |
| Hold Up Time (Typ.) | 16ms/230VAC; 10ms/115VAC at full load |
| Input | |
| Voltage Range | 90 ~ 264VAC; 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)] |
| Frequency Range | 47 ~ 63Hz |
| Efficiency (Typ.) | 88.5% |
| AC Current (Typ.) | 2.25A/115VAC; 1.3A/230VAC |
| Inrush Current (Typ.) | 20A/115VAC; 35A/230VAC |
| Leakage Current | <1mA / 240VAC |
| Protection | |
| Overload | 105 ~ 130% rated output power; Protection type: Constant current limiting, recovers automatically after fault condition is removed |
| Over Voltage | 56 ~ 65V; Protection type: Shut down o/p voltage, re-power on to recover |
| Over Temperature | Shut down o/p voltage, re-power on to recover |
| Environment | |
| Working Temperature | -20 ~ +60°C (Refer to "Derating Curve") |
| Working Humidity | 20 ~ 95% RH, non-condensing |
| Storage Temperature / Humidity | -40 ~ +85°C, 10 ~ 95% RH |
| Temperature Coefficient | ±0.03%/°C (0 ~ 50°C) |
| Vibration | Component: 10 ~ 500Hz, 2G, 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
| Safety & EMC | |
| Safety Standards | UL508, TUV BS EN/EN62368-1, EAC TP TC 004, BSMI CNS15598-1, BIS IS13252(Part1): 2010/IEC 60950-1:2005 approved; (meet BS EN/EN60204-1) |
| Withstand Voltage | I/P-O/P: 3KVAC; I/P-FG: 2KVAC; O/P-FG: 0.5KVAC |
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25°C / 70% RH |
| EMC Emission | Compliance to BS EN/EN55032 (CISPR32) Class A, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS15936 Class A |
| EMC Immunity | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2); heavy industry level, criteria A, EAC TP TC 020 |
| Other | |
| MTBF | 2718.3K hrs min. Telcordia SR-332 (Bellcore); 474.7K hrs min. MIL-HDBK-217F (25°C) |
| Dimension (W*H*D) | 40*125.2*113.5mm |
| Packing | 0.6Kg; 20pcs/13Kg/1.02CUFT |